Fisher™ FIELDVUE™ L2t Liquid Level Controller

View Product Page
L2t Cover
The cover is lockable with either a thumb screw or utilizing the padlock eye
Close
Conduit Entry (1/2)
Flexible access points allow easy wiring to the terminal box available in ½” NPT Imperial connections.
Close
Position Transmitter
A linear non-contact position transmitter that produces an analog 4-20 mA signal with HART communications.
Close
L2 Sensor
A mechanical lever system with a 2 inch NPT connection to the vessel. This holds the displacer and transmits level measurements to the input beam.
Close
Displacer and Displacer Rod
The displacer may be adjusted in the field for vertical or horizontal operation without additional parts. There are two displacer options available.
Close
Conduit Entry (2/2)
Flexible access points allow easy wiring to the terminal box available in ½” NPT Imperial connections.
Close
L2t Cover
The cover is lockable with either a thumb screw or utilizing the padlock eye
Close
Conduit Entry (1/2)
Flexible access points allow easy wiring to the terminal box available in ½” NPT Imperial connections.
Close
L2 Sensor
A mechanical lever system with a 2 inch NPT connection to the vessel. This holds the displacer and transmits level measurements to the input beam.
Close
Displacer and Displacer Rod
The displacer may be adjusted in the field for vertical or horizontal operation without additional parts. There are two displacer options available.
Close
Conduit Entry (2/2)
Flexible access points allow easy wiring to the terminal box available in ½” NPT Imperial connections.
Close
Switch 1 and Switch 2
Switch 1 and 2 are 30VDC at 1 amp maximum that are configurable solid state, dry contact limit switches. 
Close
Loop Terminal
4-20 mA with HART connection
Close
Configuration Lock Switch
A dip switch that enables or disables protection.
Close
Fault High or Low Switch
A dip switch that sets the transmitter fail high (HI) or low (LO).
Close
Push Button Calibration
The Push Buttons permit calibration without the use of a handheld or host.
Close
LED Status
LED shows the valve health status.
NE107 Valve Health Indicators
Solid
Good
Blinking
Maintenance Required
Blinking
Out of Specification
Blinking
Check Function
Solid
Failed
Close
Bias Spring and Adjuster
Used to adjust the calibrated scale up or down the displacer.
Close
Array and Input Beam
The Input Beam and Array convert the motion of the L2 sensor to magnetic input registered by the Position Transmitter.
Close
L2t Cover
The cover is lockable with either a thumb screw or utilizing the padlock eye
Close
Conduit Entry (1/2)
Flexible access points allow easy wiring to the terminal box available in ½” NPT Imperial connections.
Close
Position Transmitter
A linear non-contact position transmitter that produces an analog 4-20 mA signal with HART communications.
Close
Conduit Entry (2/2)
Flexible access points allow easy wiring to the terminal box available in ½” NPT Imperial connections.
Close
L2 Sensor
A mechanical lever system with a 2 inch NPT connection to the vessel. This holds the displacer and transmits level measurements to the input beam.
Close
Displacer and Displacer Rod
The displacer may be adjusted in the field for vertical or horizontal operation without additional parts. There are two displacer options available.
Close