Terminal Box
Standard construction for both Intrinsically Safe (IS) and Explosion Proof (Exd) requirements
Close
Optional Pneumatic Module
The Pneumatic Module can be used to control a single acting, pneumatic actuator.
Close
Local User Interface (LUI)
The LUI enables access to operational and loop information
Close
Conduit Entry (1/2)
Flexible access points allow easy wiring to the terminal box available in ½” NPT Imperial connections.
Close
Conduit Entry (2/2)
Flexible access points allow easy wiring to the terminal box available in ½” NPT Imperial connections.
Close
Pneumatic Ports
Housing is available with ¼” NPT Imperial pneumatic connections.
Close
Mountings
Leverages FIELDVUE™ non-contact mountings. Additionally, pipe stand mounting is available.
Close
Optional Integrated Pressure Sensor
Pressure sensor ranges from 0 to 5000 psi (0 – 345 bar) and can be used with or without the Optional Pneumatic Module.
Close
Integrated Pneumatic Output
For mountings to Fisher™ actuators with an integral air passage eliminating the need for external tubing and fittings.
Close
Hall Effect Sensor
Linkage-less non-contact position feedback technology eliminates issues associated with moving parts including wear, loosening, corrosion, and vibration damage.
Close
Terminal Box
Standard construction for both Intrinsically Safe (IS) and Explosion Proof (Exd) requirements
Close
Optional Pneumatic Module
The Pneumatic Module can be used to control a single acting, pneumatic actuator.
Close
Optional Pneumatic Module
The Pneumatic Module can be used to control a single acting, pneumatic actuator.
Close
Navigation Buttons
The buttons are protected from the elements with a button cover.
Close
Conduit Entry (1/2)
Flexible access points allow easy wiring to the terminal box available in ½” NPT Imperial connections.
Close
Conduit Entry (2/2)
Flexible access points allow easy wiring to the terminal box available in ½” NPT Imperial connections.
Close
Pneumatic Ports
Housing is available with ¼” NPT Imperial pneumatic connections.
Close
I/P
I/P leverages the Fisher™ FIELDVUE™ field-proven core technology
Close
Relay
Relay leverages the Fisher™ FIELDVUE™ field-proven core technology
Close
Mountings
Leverages FIELDVUE™ non-contact mountings. Additionally, pipe stand mounting is available.
Close
Optional Integrated Pressure Sensor
Pressure sensor ranges from 0 to 5000 psi (0 – 345 bar) and can be used with or without the Optional Pneumatic Module.
Close
Integrated Pneumatic Output
For mountings to Fisher™ actuators with an integral air passage eliminating the need for external tubing and fittings.
Close
Hall Effect Sensor
Linkage-less non-contact position feedback technology eliminates issues associated with moving parts including wear, loosening, corrosion, and vibration damage.
Close
Analog Input 2 (AI2)
AI2 can read a 4-20 mA signal. AI2 can provide loop power.
Close
Serial RS485
The Serial RS485 port supports Modbus RTU.
Close
RS485 Resistor Switch
The RS485 Resistor Switch is used for multidrop.
Close
Analog Output (AO)
The AO provides a 4-20 mA powered output.
Close
Write Lock Switch
The Write Lock Switch prevents configuration and calibration changes to the instrument.
Close
Analog Input 1 (AI1)
AI1 can read a 4-20 mA signal.
Close
Ethernet Port
The Ethernet Port supports Modbus TCP and HART-IP (common and universal commands).
Close
Power
The DPC2K requires 9-28 VDC with a base consumption of 1W.
Close